This article explores the sources of error in underwater heart rate measurement, comparing the accuracy of optical green-light sensors (PPG) and chest strap heart rate monitors (ECG-based) in swimming environments.
Sources of Error in Optical Heart Rate Sensing
Optical heart rate sensors (used in most sports watches) estimate heart rate by shining green-light LEDs onto the skin and detecting changes in reflected light from blood flow. In swimming scenarios, there are three main sources of error:
- Water intrusion interference: Water seeps through the gap between the strap and skin, altering the contact between the sensor and skin and disrupting the stability of the optical signal
- Repeated wrist muscle contraction: The pulling motion repeatedly compresses the wrist muscles and subcutaneous tissue, making the optical signal susceptible to contamination from muscle blood flow signals, which are difficult to distinguish from heartbeat signals
- Cold-induced vasoconstriction: In colder water, peripheral blood vessels constrict, reducing blood flow to the skin surface and weakening the optical signal strength itself
Relative Advantages and Limitations of Chest Strap Heart Rate Monitors
Chest straps use electrodes to directly detect the heart’s electrical signals (similar to a simplified ECG), and are unaffected by changes in superficial skin blood flow. In theory, they offer higher accuracy and serve as the “gold standard” reference used in most sports science research. However, chest straps still have limitations in swimming: they require good contact to maintain signal stability, prolonged swimming may cause electrode loosening due to skin sweating/water ingress, and some chest strap products do not have sufficient waterproof ratings to withstand extended submersion.
Comparison of Error Magnitudes Between the Two Sensing Methods (Illustrative)
| Scenario | Optical Sensing Error Magnitude | Chest Strap Sensing Error Magnitude |
|---|---|---|
| Steady-state swimming (constant pace cruising) | Moderate (±5-10 bpm) | Low (±2-3 bpm) |
| High-intensity interval swimming | High (±10-20 bpm or more) | Low to moderate |
| Cold water environments | Further degradation | Less affected |
Core Research Conclusions and Practical Recommendations
- Choose chest straps for high-intensity training: If you need precise heart rate zone training (e.g., interval workouts), it is recommended to use a chest strap heart rate monitor with sufficient waterproof rating
- Optical watches as trend reference: Although optical sensing data contains errors, it can still serve as a reference for long-term training trends and overall intensity distribution; there is no need to completely abandon it due to errors
- Verify device fit: Regardless of the sensing method, confirming that the device fits snugly but comfortably before training is the most direct and effective way to reduce errors
- Combine with perceived exertion: When underwater heart rate data is unstable, the Rating of Perceived Exertion (RPE) scale can be used as a supplementary aid for pace adjustment
Common Research Q&A (FAQ)
Q: Why does watch heart rate often fluctuate erratically during swimming?
A: This is mostly noise caused by optical signals being interfered with by water flow and wrist muscle movement, rather than actual dramatic heart rate fluctuations. It is recommended to interpret using trend lines rather than single-point values.
Q: Are all chest strap heart rate monitors suitable for swimming?
A: No. You need to confirm that the product explicitly indicates a waterproof rating suitable for underwater use and the signal transmission method (some chest straps using Bluetooth transmission will lose signal underwater; models with onboard memory storage for underwater use should be selected).
References and Academic Citations
- Journal of Sports Sciences — Research direction related to accuracy comparison of wearable device heart rate measurement.
- IEEE Journal of Biomedical and Health Informatics — Literature related to noise processing of optical heart rate sensing signals.
Further Reading
- Research Review: Underwater Heart Rate Error Analysis: Comparison of Optical Green-Light Sensors and Chest Strap Heart Rate Monitors in Swimming Report: Biomechanical Quantification Experimental Report (No. 1335)
- Research Review: Underwater Heart Rate Error Analysis: Comparison of Optical Green-Light Sensors and Chest Strap Heart Rate Monitors in Swimming Report: Biomechanical Quantification Experimental Report (No. 924)
- Research Review: Underwater Heart Rate Error Analysis: Comparison of Optical Green-Light Sensors and Chest Strap Heart Rate Monitors in Swimming Report: Biomechanical Quantification Experimental Report (No. 555)
- Research Review: Underwater Heart Rate Error Analysis: Comparison of Optical Green-Light Sensors and Chest Strap Heart Rate Monitors in Swimming Report: Biomechanical Quantification Experimental Report (No. 315)
松運深水池拍攝 作品 防寒衣品牌
8 年前
西進武嶺 免費訓練分析服務 Intervals | 練不夠還是練過頭?你哪一種類型選手?AI模型告訴你! | 備戰神器 | 公路車 訓練 | CT Yeh
4 年前
[防寒衣體驗] 鐵人魂 三鐵 防寒衣試穿會 於松運 深水游泳池 鯨魚池
8 年前
3D 列印車褲墊 / 舒適改善? / 無痕 x 分區壓縮 / ATK & Decider系列 / JE22黑科技 / #公路車 #CTYEH
11 個月前
#公路車 #Vo2Max #最大攝氧量 測驗 體驗 | 心肺測試
6 年前
2022 前十五大自行車錶 !? 兩萬名車友大數據統計 | 你的上榜了嗎? | 菁英車友都用哪些錶? | Bryton Garmin 誰能拔得頭籌?| 車錶推薦 | 公路車 CT Yeh
4 年前
2016/01/11 - 單車 風櫃嘴 夜騎 穩定器測試加速版
10 年前
風櫃嘴時間 預測西進武嶺時間?13000名車友統計數據分析告訴你 !
5 年前